# $Id: rockwell-k56,v 1.1.1.1 2005/11/11 21:32:01 faxguy Exp $ # # HylaFAX Facsimile Software # # Copyright (c) 1990-1996 Sam Leffler # Copyright (c) 1991-1996 Silicon Graphics, Inc. # HylaFAX is a trademark of Silicon Graphics, Inc. # # Permission to use, copy, modify, distribute, and sell this software and # its documentation for any purpose is hereby granted without fee, provided # that (i) the above copyright notices and this permission notice appear in # all copies of the software and related documentation, and (ii) the names of # Sam Leffler and Silicon Graphics may not be used in any advertising or # publicity relating to the software without the specific, prior written # permission of Sam Leffler and Silicon Graphics. # # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. # # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE # OF THIS SOFTWARE. # # # Configuration for a Rockwell AC/K56-based Class 2 modem. # based upon work of Mark J. Bailey, Jonathan Mau and Glenn Burkhardt. # Multitech MT5600ZDX # Diamond Multimedia SupraExpress 56e PRO # Zoom Telephonics 56Kx # (and others) # # This configuration file sets up the modem to run at 38.4 for # sending and for receiving. XON/XOFF is used for flow control # which also works for data connections. Adaptive answer support # is reliable, but to use it you must also enable ModemWaitForConnect # to force the server to skip intermediate status messages and # wait for the "CONNECT" message. # # CONFIG: CLASS2: Rockwell-MultiModemZDX*-* # CONFIG: CLASS2: ROCKWELL-AC/K56*-* # CONFIG: CLASS2: CONEXANT-AC/K56*-* # CONFIG: CLASS2: CONEXANT-V90-* # # BEGIN-SERVER # END-SERVER # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # ModemType: Class2 # use class 2 interface ModemRate: 19200 ModemFlowControl: xonxoff # default ModemWaitForConnect: yes # wait for CONNECT on answer # #ModemResetCmds: AT&F2 # what you want for a Supra ModemNoFlowCmd: AT&K # disable flow control cmd ModemHardFlowCmd: AT&K3 # hardware flow control cmd ModemSoftFlowCmd: AT&K4 # software flow control cmd ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset ModemSetupDCDCmd: AT&C1 # DCD follows carrier ModemSetupAACmd: AT+FCLASS=0;+FAA=1 # enable in class 0 # ModemSendFillOrder: LSB2MSB # as expected ModemRecvFillOrder: MSB2LSB # opposite of what makes sense Class2RecvDataTrigger: "\022" # a la 2388-B